Working Principle of Permanent Magnet VFD Screw Air Compressor

It consists of two core parts: compression principle of screw airend and energy-saving principle of variable frequency drive system.
 

1. Basic Compression Principle of Screw Airend

A pair of meshing male and female rotors rotates inside the airend to compress air by changing the sealed cavity volume.

Intake Stage: The rotor groove aligns with the air inlet, and atmospheric air flows into the sealed cavity.

Compression Stage: As rotors keep rotating, the cavity volume shrinks continuously, squeezing air and raising pressure gradually.

Discharge Stage: When the cavity turns to the exhaust port, high-pressure air with target pressure is delivered out of the airend.

Different from traditional fixed-speed compressors with belt or gear transmission, PM models adopt direct coaxial connection between motor and rotors, eliminating transmission power loss.

 

2. Operating Principle of Permanent Magnet Motor (Core of Energy Saving)

This machine is equipped with IE5 high-efficiency permanent magnet synchronous motor embedded with permanent magnets. The energized stator generates rotating magnetic field to drive the rotor to rotate synchronously.

No copper loss and iron loss on rotors that exist in ordinary asynchronous motors;

Maintains ultra-high efficiency even at low speed or standby state, saving 30%~40% power compared with regular compressors.

 

3. VFD Speed Regulation Principle (Adjust Air Output On Demand)

Air consumption in factories always fluctuates, and the frequency converter matches output flow automatically:

Pressure sensors monitor pipeline air pressure in real time.

When air usage rises and pipeline pressure drops: The converter speeds up the motor to boost air output and stabilize pressure.

When air usage falls and pipeline pressure rises: The converter slows down the motor to reduce air production.

If no air is consumed temporarily: The unit runs at low standby speed, avoiding idle power waste of fixed-speed compressors.

 

4. Complete Working Flow of The Whole Machine

Air enters via air filter → Permanent magnet VFD motor drives screw rotors for compression → Mixture of air and lubricant is discharged → Oil-gas separator separates lubricating oil → Cool down the air → Purified by refrigerated dryer and precision filters → Stabilized air stored in air tank → Clean stable high-pressure air supplied to laser cutters and processing equipment.

 

 

Common Faults & Solutions of Permanent Magnet VFD Screw Air Compressor

 

1. Compressor fails to start

 

Fault Causes

Emergency stop button is pressed down;

Power supply phase missing, low voltage or loose wiring;

Over-temperature protection triggered;

Fault alarm locked on PLC controller.

Solutions

Reset the emergency stop button;

Check three-phase power cable, voltage and terminal connections;

Wait for the unit to cool down, clean radiator and cooling fan;

Clear fault codes on the touch screen and restart the machine.

 

2. High exhaust temperature / Overheat alarm shutdown

 

Fault Causes

Insufficient lubricant oil or oil aging;

Blocked oil filter, air filter or oil cooler;

Cooling fan broken or heat dissipation channel clogged;

Ambient workshop temperature over 45℃.

Solutions

Add or replace special compressor lubricant oil;

Replace blocked filters and clean the oil cooler thoroughly;

Repair or change the cooling fan, tidy up ventilation space around the machine;

Improve workshop ventilation or install extra exhaust fans.

 

3. Unstable air pressure, large pressure fluctuation

 

Fault Causes

Air leakage on pipeline, tank or joints;

Pressure sensor damaged or loose signal wire;

VFD parameter setting error;

Large sudden fluctuation of air consumption.

Solutions

Inspect all pipelines and seal leaking points;

Reconnect or replace the pressure sensor;

Recalibrate pressure parameters on the control panel;

Match a proper air storage tank to buffer pressure.

 

4. High power consumption / Low energy-saving effect

 

Fault Causes

Air filter & oil separator blocked, increasing operating load;

Permanent magnet motor demagnetized;

VFD frequency parameter misadjusted;

Serious air leakage of post-processing pipelines.

Solutions

Replace aging filters and oil separator core;

Inspect PM motor by professional technician;

Reset factory VSD operation parameters;

Detect and repair all air leakage positions.

 

 

5. Abnormal loud noise & vibration

 

Fault Causes

Loose fixing bolts of airend, motor or base;

Damaged shock-absorbing foot pads;

Foreign matter inside screw airend;

Unbalanced cooling fan blade.

Solutions

Tighten all fixing bolts evenly;

Replace worn shock pads;

Disassemble and clean the airend, check rotor damage;

Replace deformed cooling fan blades.

 